The body control module (SBM) controls the courtesy lamps for theater dimming. The SBM fades the lamps by controlling CKT 156.
The SBM detects a short to ground or an open in CKT 156.
• | DTC B2452 is stored in the SBM memory. |
• | No driver warning message is displayed for this DTC. |
• | A short to ground is no longer detected by the SBM in CKT 156. |
• | An open is no longer detected by the SBM in CKT 156. |
• | A history DTC clears after 50 consecutive ignition cycles if the condition for the fault is no longer present. |
The following conditions may cause an intermittent malfunction to occur:
• | An intermittent short to ground in CKT 156 |
• | An intermittent open in CKT 156 |
• | A short to ground or an open internally to the SBM |
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Body Control Module Diagnostic System Check ? | -- | Go to Step 2 | |
2 |
Is voltage present? | -- | Go to Step 3 | Go to Step 4 |
3 |
Did you complete the repair? | -- | Go to Step 5 | -- |
4 | Repair the open or a short to ground in CKT 156. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 5 | -- |
5 |