Removal Procedure
The actuators are specifically designed for the right and left side
of the heater and A/C module. When servicing an actuator, ensure that you
replace the actuator with the correct service part for the position being
serviced.
- Remove the sound insulators, as needed, in order to gain access
to the actuators. Refer to
Instrument Panel Insulator Panel Replacement
in Instrument Panel, Gauges, and Console.
- Remove the knee bolster, as needed. Refer to Knee Bolster Replacement
in Instrument Panel, Gauges, and Console.
- Remove the console, as needed. Refer to
Console Replacement
in Instrument Panel, Gauges, and Console.
- Remove the trim, as needed. Refer to Trim Panel Replacement in
Instrument Panel, Gauges, and Console.
- Disconnect the electrical connector from the actuator.
- Remove the screws retaining the actuator.
- Remove the actuator.
Installation Procedure
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the actuator
with mounting screws.
Tighten
Tighten the screws to 1 N·m (12 lb in).
- Connect the electrical connector.
- Install the knee bolster. Refer to Knee Bolster Replacement in
Instrument Panel, Gauges, and Console.
- Install the console. Refer to
Console Replacement
in Instrument Panel, Gauges, and Console.
- Install the trim. Refer to Trim Panel Replacement in Instrument
Panel, Gauges, and Console.
Important: After the actuator has been replaced, the actuator must be recalibrated
for proper travel. The ignition must be cycled on for 3 minutes in
order to allow the programmer and the actuators time to recalibrate for
proper travel.
- Install the sound insulators. Refer to
Instrument Panel Insulator Panel Replacement
in Instrument Panel, Gauges, and
Console.