Important: Be sure to record the relative humidity and ambient temperature conditions at the time of the test.
Temperature | Humidity | Low Gauge Pressure | High Gauge Pressure | Center Outlet Temperature |
---|---|---|---|---|
21°-27°C (70°- 80°F) | Less than 50% | 165-234 kPa (24- 34 psi) | 793-1310 kPa (115-190 psi) | 3°-9-C (38°-34°F) |
More than 50% | 172-255 kPa (25- 37 psi) | 793-1379 kPa (115-200 psi) | 4°-13°C (40°- 55°F) | |
27°-33°C (80°- 90°F) | Less than 50% | 193-262 kPa (28- 38 psi) | 965-1482 kPa (140-215 psi) | 3°-13°C (38°- 55°F) |
More than 50% | 207-276 kPa (30- 40 psi) | 1034-1620 kPa (150-235 psi) | 7°-18°C (45°- 65°F) | |
33°-38°C (90°- 100°F) | Less than 40% | 234-296 kPa (34- 43 psi) | 1138-1793 kPa (165-260 psi) | 7°-17°C (45°- 63°F) |
More than 40% | 251-331 kPa (36- 48 psi) | 1276-1862 kPa (185-270 psi) | 13°-20°C (55°- 68°F) | |
38°-44°C (100°- 110°F) | Less than 20% | 276-338 kPa (40- 49 psi) | 1448-2000 kPa (210-290 psi) | 12°-18°C (53°- 64°F) |
More than 20% | 296-359 kPa (43- 52 psi) | 1517-2137 kPa (220-310 psi) | 14°-21°C (58°- 70°F) |