Diagnostic Instructions
Circuit/System Description
The driver door switch (DDS) and passenger door switch (PDS) supply voltage to the outside rearview mirror heater elements upon receipt of a serial data message from the HVAC module indicating that the rear defrost system is active. The door module supplies
B+ through the driver/passenger mirror heating element supply voltage circuit when a request is seen. Ground is applied through the driver/passenger mirror heating element low reference circuit.
Reference Information
Schematic Reference
Outside Rearview Mirror Schematics
Connector End View Reference
Mirror Connector End Views
Description and Operation
Outside Mirror Description and Operation
Electrical Information Reference
Circuit/System Verification
- Ignition ON, press the rear window defogger switch. Verify the rear window defogger indicator illuminates.
- Press the rear window defogger switch. Verify both the left and right outside mirror glass become warm.
Circuit/System Testing
- Ignition OFF, disconnect the harness connector C1 at the outside rearview mirror.
- Ignition OFF, test for less than 300 ohms of resistance between the low reference circuit terminal 3 and ground.
⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the appropriate door module. |
- Connect a test lamp between the supply voltage circuit terminal 4 and ground.
- Ignition ON, command the mirror heater ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.
⇒ | If the test lamp is always ON, test the supply voltage circuit for a short to voltage. If the circuit tests normal, replace the appropriate door module. |
⇒ | If the test lamp is always OFF, test the supply voltage circuit
for a short to ground or an open/high resistance. If the circuit tests normal, replace the appropriate door module. |
- If all circuits test normal, test or replace the outside rearview mirror face.
Repair Instructions
Perform the
Diagnostic Repair Verification
after completing the diagnostic procedure.