The HVAC programmer commands the actuator to move by suppling battery voltage. The feedback supplied to the HVAC programmer is a regulated 5 volts. The feedback voltage is a function of the motor position with a high voltage of 4-5 volts indicating full cold door position. A low voltage of less than 1 volt indicates the full hot position. Operation of the air mix door actuator can be evaluated through the Scan Tool .
The ignition is ON.
Only the full hot or full cold may be used by the system.
• | Using a Scan Tool . |
• | A history DTC will clear when 40 consecutive ignition cycles have occurred without a malfunction. |
• | HVAC programmer battery voltage is interrupted. |
Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
1 |
Does the Scan Tool show a commanded (COM) mix door position that matches the specified value? | 100% | Go to Step 2 | Go to Step 6 | ||||||
2 | Set the temperature to full hot. Does the Scan Tool show a commanded (COM) mix door position hat matches the specified value? | 0% | Go to Step 3 | Go to Step 6 | ||||||
3 | Compare the actual (ACT value shown on the Scan Tool ), values both hot and cold with the commanded (COM). Are the values within the specified range? | 0-5% | Go to Step 6 | Go to Step 4 | ||||||
4 | Inspect the driver air mix valve for the following conditions:
Are any of these conditions present? | -- | Go to Step 5 | Go to Step 6 | ||||||
5 | Repair the condition. Is the repair complete? | -- | System OK | -- | ||||||
6 | Replace the HVAC programmer. Refer to Programmer Replacement . Is the repair complete? | -- | System OK | -- |