Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the Power Door Locks System Check? | -- | Go to Step 2 | |||||||
2 |
Does the MALL module sound 1 bong for each press of the switch? | -- | Go to Step 3 | Go to Step 5 | ||||||
3 |
Is CKT 694 shorted to ground? | -- | Go to Step 4 | Go to Step 10 | ||||||
4 | Repair CKT 694 (TAN). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |||||||
5 |
Does the resistance measure within the specified range? | 0-5 ohms | Go to Step 6 | Go to Step 8 | ||||||
6 | Inspect the MALL module connector C2 for proper terminal contact at terminal C6. Refer to Intermittents and Poor Connections Diagnosis in Wiring Systems. Is the terminal contact OK? | -- | Go to Step 10 | Go to Step 7 | ||||||
7 | Repair the terminal contact at the MALL module connector C2. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |||||||
8 | Test for an open in CKT 781 (ORN/BLK) between the MALL module connector C2 terminal C6 and S252. Is CKT 781 open? | -- | Go to Step 9 | Go to Step 10 | ||||||
9 | Repair the open in CKT 781 (ORN/BLK). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |||||||
10 | Replace the MALL module. Refer to Body Control Module Replacement in Body Control Systems. Is the repair complete? | -- | -- |