Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Power Windows System Check? | -- | Go to Step 2 | |
2 | Test for an open in CKT 164 from S500 to terminal C of the power window control module. Is CKT 164 OK? | -- | Go to Step 3 | Go to Step 6 |
3 | Inspect for poor connections at the power window control module terminal A and terminal C. Refer to Intermittents and Poor Connections Diagnosis in Wiring Systems. Are the connections OK? | -- | Go to Step 4 | Go to Step 5 |
4 | Repair the poor connections. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
5 | Replace the power window control module. Refer to Door Control Module Replacement . Is the repair complete? | -- | -- | |
6 | Repair the open in CKT 164. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- |