Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Power Door Locks System Check? | -- | Go to Step 2 | |
2 |
Does the MALL module sound 1 bong for each press of the switch? | -- | Go to Step 3 | Go to Step 5 |
3 |
Does the resistance measure within the specified range? | 0-5 ohms | Go to Step 4 | Go to Step 10 |
4 | Repair the short to ground in CKT 295 (GRY). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
5 |
Does the resistance measure within the specified range? | 0-5 ohms | Go to Step 6 | Go to Step 8 |
6 | Inspect the MALL module connector C2 for proper terminal contact at terminal C7. Refer to Intermittents and Poor Connections Diagnosis in Wiring Systems. Is the terminal contact OK? | -- | Go to Step 10 | Go to Step 7 |
7 | Repair the terminal contact at the MALL module connector C2. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
8 | Test for an open in CKT 780 (RED/BLK) between the MALL module connector C2 terminal C7 and S248. Is CKT 780 open? | -- | Go to Step 9 | Go to Step 10 |
9 | Repair the open in CKT 780 (RED/BLK). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
10 | Replace the MALL module. Refer to Body Control Module Replacement in Body Control Systems. Is the repair complete? | -- | -- |