Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
1 | Was the entire Backup Lights System Check performed? | -- | Go to Backup Lamp System Check | |||||||
2 |
Is the voltage within the specified range? | 10-15 V | ||||||||
3 | Connect a DMM from the suspect backup lamp connector cavity A (LT GRN) to cavity G (BLK). Is the voltage within the specified range? | 10-15 V | ||||||||
4 | Replace the suspect backup lamp.
Is the repair complete? | -- | Go to Backup Lamp System Check | -- | ||||||
5 | Repair the open in CKT 24 (LT GRN) between S406 and the suspect backup lamp. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Backup Lamp System Check | -- | ||||||
6 | Repair the open in CKT 1350 (BLK) between S404 and the suspect backup lamp. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Backup Lamp System Check | -- |