Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the entire Foglights System Check? | -- | Go to Step 2 | Go to Fog Lights System Check |
2 | Disconnect the fog lamp switch connector. Do the fog lamps turn off? | -- | Go to Step 6 | Go to Step 3 |
3 | Disconnect the lamp control module connector C2. Do the fog lamps turn off? | -- | Go to Step 7 | Go to Step 4 |
4 | Remove the fog lamps relay from the RH IP fuse block. Do the fog lamps turn off? | -- | Go to Step 8 | Go to Step 5 |
5 | Repair the short to voltage in CKT 34 (PPL). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Fog Lights System Check | -- |
6 | Replace the fog lamp switch. Refer to Instrument Cluster Trim Panel Replacement in Instrument Panel, Gauges and Console. Is the repair complete? | -- | Go to Fog Lights System Check | -- |
7 | Replace the lamp control module. Refer to Lamp Control Module Replacement . Is the repair complete? | -- | Go to Fog Lights System Check | -- |
8 | Replace the fog lamps relay. Is the repair complete? | -- | Go to Fog Lights System Check | -- |