Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the entire Foglights System Check? | -- | Go to Step 2 | Go to Fog Lights System Check |
2 |
Is the voltage within the specified range? | 10-15V | Go to Step 3 | Go to Step 9 |
3 | Connect a DMM from the fog lamp switch connector cavity A (BRN) to cavity B (BLK) Is the voltage within the specified range? | 10-15V | Go to Step 4 | Go to Step 10 |
4 |
Is the voltage within the specified range? | 10-15V | Go to Step 5 | Go to Step 11 |
5 | Connect a DMM from the fog lamps relay connector cavity 30 (ORN) to ground. Is the voltage within the specified range? | 10-15V | Go to Step 6 | Go to Step 13 |
6 | Connect a fused jumper from the fog lamps relay connector cavity 30 (ORN) to cavity 87 (PPL) Do the fog lamps turn on? | -- | Go to Step 7 | Go to Step 14 |
7 |
Do the fog lamps turn on? | -- | Go to Step 8 | Go to Step 15 |
8 | Replace the LCM. Refer to Lamp Control Module Replacement . Is the repair complete? | -- | Go to Fog Lights System Check | -- |
9 | Repair the open in CKT 9 (BRN) between S204 and the fog lamp switch. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Fog Lights System Check | -- |
10 | Repair the open in CKT 1250 (BLK) between S213 and the fog lamp switch. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Fog Lights System Check | -- |
11 | Inspect CKT 317 (YEL) for an open or short to ground. Refer to Testing for Continuity or Testing for Short to Ground in Wiring Systems. Is CKT 317 (YEL) OK? | -- | Go to Step 12 | Go to Step 16 |
12 | Replace the fog lamp switch. Refer to Instrument Cluster Trim Panel Replacement in Instrument Panel, Gauges and Console. Is the repair complete? | -- | Go to Fog Lights System Check | -- |
13 | Repair the open in CKT 1440 (ORN). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Fog Lights System Check | -- |
14 | Repair the open or short to ground in CKT 34 (PPL). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Fog Lights System Check | -- |
15 | Inspect CKT 1317 (DK GRN/WHT) for an open. Refer to Testing for Continuity in Wiring Systems. Is CKT 1317 (DK GRN/WHT) OK? | -- | Go to Step 17 | Go to Step 16 |
16 | Repair the suspect wiring. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Fog Lights System Check | -- |
17 | Replace the fog lamps relay. Is the repair complete? | -- | Go to Fog Lights System Check | -- |
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the entire Foglights System Check? | -- | Go to Step 2 | Go to Fog Lights System Check |
2 |
Is the voltage within the specified range? | 10-15V | Go to Step 3 | Go to Step 8 |
3 |
Is the voltage within the specified range? | 10-15V | Go to Step 4 | Go to Step 9 |
4 | Connect a DMM from the fog lamps relay connector cavity 30 (ORN) to ground. Is the voltage within the specified range? | 10-15V | Go to Step 5 | Go to Step 10 |
5 | Connect a fused jumper between the fog lamps relay connector cavity 30 (ORN) and cavity 87 (PPL). Do the fog lamps turn on? | -- | Go to Step 6 | Go to Step 11 |
6 |
Do the fog lamps turn on? | -- | Go to Step 7 | Go to Step 12 |
7 | Replace the LCM. Refer to Lamp Control Module Replacement . Is the repair complete? | -- | Go to Fog Lights System Check | -- |
8 | Repair the open in CKT 9 (BRN) between S204 and the fog lamp switch. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Fog Lights System Check | -- |
9 | Inspect CKT 317 (YEL) for an open or short to ground. Refer to Testing for Continuity or Testing for Short to Ground in Wiring Systems. Is CKT 317 (YEL) OK? | -- | Go to Step 13 | Go to Step 14 |
10 | Repair the open or short to ground in CKT 1440 (ORN). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Fog Lights System Check | -- |
11 | Repair the open or short to ground in CKT 34 (PPL). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Fog Lights System Check | -- |
12 | Inspect CKT 1317 (DK GRN/WHT) for an open. Refer to Testing for Continuity in Wiring Systems. Is CKT 1317 (DK GRN/WHT) OK? | -- | Go to Step 15 | Go to Step 14 |
13 | Replace the fog lamp switch. Refer to Instrument Cluster Trim Panel Replacement in Instrument Panel, Gauges and Console. Is the repair complete? | -- | Go to Fog Lights System Check | -- |
14 | Repair the suspect wiring. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Fog Lights System Check | -- |
15 | Replace the fog lamps relay. Is the repair complete? | -- | Go to Fog Lights System Check | -- |