The PCM tests the EGR system during deceleration by momentarily commanding the EGR valve open while monitoring the Manifold Absolute Pressure (MAP) sensor signal. When the EGR valve is opened, the PCM should see a proportional increase in MAP. If the expected increase in MAP is not seen, the PCM notes the amount of error that was detected and adjusts an internal fail counter towards a fail threshold level. When the fail counter exceeds the fail threshold level, the PCM will set DTC P0401. The number of test samples required to accomplish this may vary according to the amount of detected flow error.
Normally, the PCM will only allow one EGR flow test sample to be taken during an ignition cycle. To aid in verifying a repair, the PCM allows twelve test samples during the first ignition cycle following a scan tool Clear Info or a battery disconnect. Between nine and twelve samples should be sufficient for the PCM to determine adequate EGR flow and pass the EGR test if the system is operating correctly.
MAP changes monitored during the EGR flow test indicate insufficient EGR flow.
Important: If the EGR valve shows signs of excessive heat, check the exhaust system for blockage (possibly a plugged catalytic converter) using the Restricted Exhaust System Check.
To verify a repair, clear info with the scan tool and run the EGR flow test keeping the following items in mind:
Check for the following conditions:
Reviewing the Fail Records vehicle mileage since the diagnostic test last failed may help determine how often the condition that caused the DTC to be set occurs. This may assist in diagnosing the condition.
Step
Action
Value(s)
Yes
No
1
Was the Powertrain On-Board Diagnostic (OBD) System Check performed?
--
Go to Step 2
Go to Powertrain On Board Diagnostic (OBD) System Check
2
Was a problem found?
Go to Step 5
Go to Step 3
3
Go to Step 4
4
Go to Diagnostic Aids
5
Note test result; does scan tool indicate DTC P0401 Test Ran and Passed?
System OK