Generator
The CS-130 generator is electrically similar to earlier models. The
generator features the following major components:
• | The rotor with slip rings and brushes |
The pulley and the fan cool the slip ring and the frame.
The CS stands for charging system. The 130 denotes the outside
diameter, in millimeters, of the stator laminations. The generator is rated
at 105 amperes.
The generator features permanently lubricated bearings. Service should
only include tightening of mount components. Otherwise, replace the generator
as a complete unit.
Regulator
The voltage regulator controls the rotor field current in order to limit
the system voltage. When the field current is on, the regulator switches the
current on and off at a rate of 400 cycles per second in order to
perform the following functions:
• | Obtain the correct average current needed for proper system voltage
control |
At high speeds, the on-time may be 10 percent with the off-time
at 90 percent. At low speeds, the on-time may be 90 percent
and the off-time 10 percent.