• | J 38758 Parasitic Draw Test Switch Tool |
• | J 39200 Digital Multimeter (DMM) |
Notice: Do not turn the parasitic draw test switch to the OFF position with the engine running. Damage will occur to the vehicle's electrical system.
Notice: The test switch must be in the ON position when removing the fuses in order to maintain continuity in the electrical system. This avoids damaging the digital multimeter due to accidental overloading, such as a door being opened to change a fuse.
Important: The switch knob on the J 38758 is marked ON and OFF. When the switch knob is in the ON position, the circuit is closed and electrical current will pass through the switch. When the switch knob is in the OFF position, the circuit is open and electrical current will not pass through the switch.
• | When there is a current reading of 2 A or less, turn the J 38758 knob to the ON position. Continuity is maintained in the electrical system. |
• | Then, switch the DMM down to the 2 A scale for a more accurate reading when the J 38758 knob is turned OFF. |
• | Divide the reserve capacity by 4. |
• | Compare this to the DMM milliampere reading taken in the previous step. |
• | The parasitic current drain should not exceed this number. |
• | Example: If a battery has a reserve capacity of 100 amperes, the current drain should not exceed 25 minutes. |
Notice: The test switch must be in the ON position when removing the fuses in order to maintain continuity in the electrical system. This avoids damaging the digital multimeter due to accidental overloading, such as a door being opened to change a fuse.
Component | Approximate Current Draw (mA) Typical | Approximate Current Draw (mA) Maximum |
---|---|---|
ALC (After 7 Minute Time Out) | -- | 1.0 |
Blower Control Module (C68 or CJ2) | 1.0 | 2.0 |
Compact Disc (CD) Player | 1.8 | 3.5 |
Electronic Brake (& Traction) Control Module (After 4 Minute Time Out) | 1.0 | 1.5 |
Generator | 2.0 | 2.0 |
Heated Seat Control Module | 0.5 | 1.0 |
HVAC Programmer | 0.5 | 0.75 |
Instrument Cluster | 4.0 | 6.0 |
Lamp Control Module | 0.5 | 1.0 |
Lamp Monitor Control Module | 0.5 | 1.0 |
Powertrain Control Module (PCM) | 5.0 | 7.0 |
Remote Function Actuator (RFA) Module | -- | 3.8 |
Radio | 7.0 | 8.5 |
Theft Deterrent Module | 0.75 | 1.0 |