Battery Description and Operation LY7
Caution: Batteries produce explosive gases, contain corrosive acid, and supply levels
of electrical current high enough to cause burns. Therefore, to reduce the risk of
personal injury when working near a battery:
• | Always shield your eyes and avoid leaning over the battery whenever possible. |
• | Do not expose the battery to open flames or sparks. |
• | Do not allow the battery electrolyte to contact the eyes or the skin.
Flush immediately and thoroughly any contacted areas with water and get medical help. |
• | Follow each step of the jump starting procedure in order. |
• | Treat both the booster and the discharged batteries carefully when using
the jumper cables. |
Important: Because of the materials used in the manufacture of automotive lead-acid batteries,
dealers and service shops that handle them are subject to various regulations issued
by OSHA, EPA, DOT, and various state or local agencies. Other regulations may also
apply in other locations. Always know and follow these regulations when handling batteries.
Batteries that are no longer wanted must be disposed of by an approved battery
recycler and must never be thrown in the trash or sent to a landfill.
Batteries that are not part of the vehicle itself, not the battery under the
hood, must only be transported on public streets for business purposes via approved
hazardous material transportation procedures.
Battery storage, charging and testing facilities in repair shops must meet various
requirements for ventilation, safety equipment, material segregation, etc.
The maintenance free Absorbent Glass Mat (AGM) battery is the standard original
equipment battery. The battery is completely sealed except for one vent port in the
end of the cover. The vent port allows the small amount of gas that is produced in
the battery to escape when pressures exceed 2 psi. The AGM battery is a lead-acid
battery that is similar to current batteries. They use glass mats that absorb electrolyte
that are pressed between the plates instead of immersing the plates in electrolyte.
This allows a smaller, lighter battery with the same amount of power which is less
susceptible to heat.
The battery has three functions as a major source of energy:
• | Alternate source of energy with generator overload and during key off. |
The battery specification label (see typical figure) contains information about
the following:
• | The original equipment catalog number |
• | The recommended replacement model number |
Battery Ratings
A battery has two ratings:
• | Reserve capacity (RC) |
• | Cold cranking amperage (CCA) |
When a battery is replaced use a battery with similar ratings. Refer to the
battery specification label on the original battery or refer to
Battery Usage
.
Reserve Capacity (RC)
The RC is an indication of the battery's ability to produce a relatively low
amount of current over a long period of time and is also an indication of the battery's
energy storage capability. The RC rating is the amount of time in minutes it takes
a fully charged battery at 27°C (80°F) to reach a terminal voltage of 10.5 volts
when it is being discharged at a constant rate of 25 amperes. Refer to
Battery Usage
for the reserve capacity rating
of the original equipment battery.
Cold Cranking Amperage (CCA)
The cold cranking amperage is an indication of the ability of the battery to
provide high power to crank the engine at cold temperatures. The cold cranking amperage
rating is the minimum amperage the battery must maintain for 30 seconds at -18°C
(0°F) while maintaining at least 7.2 volts across its terminals. Refer to
Battery Usage
for the cold cranking amperage rating for
this vehicle.
Circuit Description
The battery positive terminal supplies battery positive voltage to the under
hood fuse block and the rear fuse block. The under hood fuse block provides a cable
connection for the generator and a cable connection for the starter.
Battery Description and Operation L26
Caution: Batteries produce explosive gases, contain corrosive acid, and supply levels
of electrical current high enough to cause burns. Therefore, to reduce the risk of
personal injury when working near a battery:
• | Always shield your eyes and avoid leaning over the battery whenever possible. |
• | Do not expose the battery to open flames or sparks. |
• | Do not allow the battery electrolyte to contact the eyes or the skin.
Flush immediately and thoroughly any contacted areas with water and get medical help. |
• | Follow each step of the jump starting procedure in order. |
• | Treat both the booster and the discharged batteries carefully when using
the jumper cables. |
Important: Because of the materials used in the manufacture of automotive lead-acid batteries,
dealers and service shops that handle them are subject to various regulations issued
by OSHA, EPA, DOT, and various state or local agencies. Other regulations may also
apply in other locations. Always know and follow these regulations when handling batteries.
Batteries that are no longer wanted must be disposed of by an approved battery
recycler and must never be thrown in the trash or sent to a landfill.
Batteries that are not part of the vehicle itself, not the battery under the
hood, must only be transported on public streets for business purposes via approved
hazardous material transportation procedures.
Battery storage, charging, and testing facilities in repair shops must meet
various requirements for ventilation, safety equipment, material segregation, etc.
The maintenance-free battery is standard. There are no vent plugs in the cover.
The battery is completely sealed except for 2 small vent holes in the side. These
vent holes allow the small amount of gas that is produced in the battery to escape.
The battery has 3 functions as a major source of energy:
• | Alternate source of energy with generator overload |
The battery specification label, example below, contains information about the
following:
• | The original equipment catalog number |
• | The recommended replacement model number |
Battery Ratings
A battery may have 3 ratings:
• | Reserve capacity (RC) |
• | Cold cranking amperage (CCA) |
When a battery is replaced, use a battery with similar ratings. Refer to the
battery specification label on the original battery or refer to
Battery Usage
.
Amp Hour (AH)
The amp hour rating of a battery is the amount of time it takes a fully charged
battery, being discharged at a constant rate of 1 amperes and a constant temperature
of 27°C (80°F), to reach a terminal voltage of 10.5 volts. Refer to
Battery Usage for the amp hour rating of the original equipment battery.
Reserve Capacity (RC)
Reserve capacity is the amount of time in minutes it takes a fully charged battery,
being discharged at a constant rate of 25 amperes and a constant temperature
of 27°C (80°F), to reach a terminal voltage of 10.5 volts. Refer to
Battery Usage for the reserve capacity rating of the original equipment battery.
Cold Cranking Amperage (CCA)
The cold cranking amperage is an indication of the ability of the battery to
crank the engine at cold temperatures. The cold cranking amperage rating is the minimum
amperage the battery must maintain for 30 seconds at -18°C (0°F)
while maintaining at least 7.2 volts. Refer to
Battery Usage