Removal Procedure
- Remove the instrument panel accessory trim plate. Refer to
Instrument Cluster Trim Panel Replacement
in Instrument
Panel, Gauges and Console.
- Remove the front floor console, if equipped. Refer to
Front Floor Console Replacement
in Instrument
Panel, Gauges and Console.
- Remove the retaining screws
from the HVAC control module.
- Pull the HVAC control module out from the instrument panel.
- Disconnect the electrical
connectors and the vacuum harness, if equipped from the HVAC control module.
- Remove the HVAC control module.
Installation Procedure
- Connect the electrical
connectors and the vacuum harness, if equipped to the HVAC control module.
- Install the HVAC control
module into the instrument panel.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the retaining
screws to secure the HVAC control module.
Tighten
Tighten the HVAC control module screws to 2 N·m (18 lb
in).
- Install the instrument panel accessory trim plate. Refer to
Front Floor Console Replacement
in Instrument
Panel, Gauges and Console.
- Install the front floor console, if equipped. Refer to
Front Floor Console Replacement
in Instrument
Panel, Gauges and Console.