Removal Procedure
- Remove the negative battery
cable. Refer to
Battery Negative Cable Disconnection and Connection
in engine electrical.
- Note the position of the EVAP hoses for installation.
- Remove the Canister purge valve electrical connector and hoses.
- Release the lock tab on the mounting bracket.
- Remove the EVAP canister purge valve.
Installation Procedure
- Bend tab on mounting
bracket to retain the EVAP purge valve.
- Install the purge valve to the mounting bracket.
Once installed pull on the purge valve to ensure that the part will
be held in place.
- Install the purge valve electrical connector and hoses.
- Reconnect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
in
engine electrical.